Hired-Hand System 500 Programs (Tunnel Model) User Manual
System 500 programs (tunnel model), Program 0,1 a b, Program 0,2 a b
System 500 Power Curtain Controller (Tunnel) Program Sheets
Rev 7/98
4801-2973
System 500 Programs (Tunnel Model)
Heat = Calefacción
Cool Neg = Cool Negative = Ventilación Negativa
Cool Stir = Ventilación por mover el aire
Cool N/T = Cool Negative Tunnel = Ventilación Negativa Túnel
Cool Tun = Cool Tunnel = Ventilación Túnel
Initial Drop is in Seconds
Unit Sensors
1 = Sensor 1
2 = Sensor 2
3 = Both Sensors
Program 0,0
A
B
Stage
Mode
Sensor(s)
Differential
Offset
Stage
Mode
Sensor(s)
Differential
Offset
1
Cool Stir
1
2
1
1
Cool Stir
1
2
1
2
Cool Stir
2
2
1
2
Cool Stir
2
2
1
3
Cool N/T
3
1
1
3
Cool N/T
3
1
1
4
Cool Tun
3
1
3
4
Cool Tun
3
1
3
5
Cool Tun
3
1
5
5
Cool Tun
3
1
5
6
Cool Tun
3
1
7
6
Cool Tun
3
1
7
7
Cool Tun
3
1
9
7
Cool Tun
3
1
9
8
Cool Tun
3
60
90
8
Cool Tun
3
60
90
Initial Drop
40
Initial Drop
40
Sensors
3
Sensors
3
Degrees Above Target
3
Degrees Above Target
3
Program 0,1
A
B
Stage
Mode
Sensor(s)
Differential
Offset
Stage
Mode
Sensor(s)
Differential
Offset
1
Cool Neg
1
1
1
1
Cool Neg
1
1
1
2
Cool Neg
2
1
1
2
Cool Neg
2
1
1
3
Cool N/T
3
2
2
3
Cool N/T
3
2
4
4
Cool Tun
3
2
5
4
Cool Tun
3
2
40
5
Cool Tun
3
3
7
5
Cool Tun
3
2
40
6
Cool Tun
3
3
10
6
Cool Tun
3
2
40
7
Cool Tun
3
3
13
7
Cool Tun
3
2
40
8
Cool Tun
3
60
90
8
Cool Tun
3
2
40
Initial Drop
40
Initial Drop
40
Sensors
3
Sensors
3
Degrees Above Target
3
Degrees Above Target
3
Program 0,2
A
B
Stage
Mode
Sensor(s)
Differential
Offset
Stage
Mode
Sensor(s)
Differential
Offset
1
Cool Neg
1
2
1
1
Cool Neg
1
2
1
2
Cool Neg
2
2
1
2
Cool Neg
2
2
1
3
Cool N/T
3
1
1
3
Cool N/T
3
1
1
4
Cool Tun
3
1
3
4
Cool Tun
3
1
3
5
Cool Tun
3
1
5
5
Cool Tun
3
1
5
6
Cool Tun
3
1
7
6
Cool Tun
3
1
7
7
Cool Tun
3
1
9
7
Cool Tun
3
1
9
8
Cool Tun
3
60
90
8
Cool Tun
3
60
90
Initial Drop
40
Initial Drop
40
Sensors
3
Sensors
3
Degrees Above Target
3
Degrees Above Target
3
Program 0,3
A
B
Stage
Mode
Sensor(s)
Differential
Offset
Stage
Mode
Sensor(s)
Differential
Offset
1
Cool Neg
1
2
2
1
Cool Neg
1
1
2
2
Cool Neg
2
20
40
2
Cool Neg
2
1
2
3
Cool N/T
2
20
40
3
Cool N/T
3
1
1
4
Cool Tun
3
20
40
4
Cool Tun
3
3
3
5
Cool Tun
3
20
40
5
Cool Tun
3
2
2
6
Cool Tun
3
20
40
6
Cool Tun
3
2
4
7
Cool Tun
3
20
40
7
Cool Tun
3
2
6
8
Cool Tun
3
20
40
8
Cool Tun
3
2
9
Initial Drop
40
Initial Drop
40
Sensors
1
Sensors
3
Degrees Above Target
3
Degrees Above Target
30