Hired-Hand System 500 Programs (Conventional Model) User Manual
System 500 programs (conventional model), Program 0,1 a b, Program 0,2 a b
System 500 Power Curtain Controller (Conventional) Program Sheets
Rev 7/97
4801-2977
System 500 Programs (Conventional Model)
Heat = Calefacción
Cool Neg = Cool Negative = Ventilación Negativa
Cool Stir = Ventilación por mover el aire
Initial Drop is in Seconds
Unit Sensors
1 = Sensor 1
2 = Sensor 2
3 = Both Sensors
Program 0,0
A
B
Stage
Mode
Sensor(s) Differential
Offset
Stage
Mode
Sensor(s) Differential
Offset
1
Cool Stir
1
1
2
1
Cool Stir
1
1
2
2
Cool Stir
1
2
3
2
Cool Stir
1
2
3
3
Cool Stir
1
2
4
3
Cool Stir
1
2
4
4
Cool Stir
3
20
40
4
Cool Stir
3
2
6
5
Cool Stir
3
20
40
5
Cool Stir
3
2
8
6
Cool Stir
3
20
40
6
Cool Stir
3
2
10
7
Cool Stir
3
20
40
7
Cool Stir
3
2
12
8
Cool Stir
3
20
40
8
Cool Stir
3
2
14
Initial Drop
40
Initial Drop
40
Sensor(s)
3
Sensor(s)
3
Degrees above Target
3
Degrees above Target
3
Program 0,1
A
B
Stage
Mode
Sensor(s) Differential
Offset
Stage
Mode
Sensor(s) Differential
Offset
1
Cool Stir
1
1
1
1
Cool Stir
3
1
1
2
Cool Stir
1
1
2
2
Cool Stir
3
1
2
3
Cool Stir
3
20
40
3
Cool Stir
3
2
3
4
Cool Stir
3
20
40
4
Cool Stir
3
2
5
5
Cool Stir
3
20
40
5
Cool Stir
3
2
6
6
Cool Stir
3
20
40
6
Cool Stir
3
2
8
7
Cool Stir
3
20
40
7
Cool Stir
3
2
9
8
Cool Stir
3
20
40
8
Cool Stir
3
2
12
Initial Drop
40
Initial Drop
40
Sensor(s)
3
Sensor(s)
3
Degrees above Target
3
Degrees above Target
3
Program 0,2
A
B
Stage
Mode
Sensor(s) Differential
Offset
Stage
Mode
Sensor(s) Differential
Offset
1
Cool Stir
1
1
0
1
Cool Stir
3
2
0
2
Cool Stir
1
40
40
2
Cool Stir
3
2
0
3
Cool Stir
1
40
40
3
Cool Stir
3
2
2
4
Cool Stir
1
40
40
4
Cool Stir
3
3
3
5
Cool Stir
1
40
40
5
Cool Stir
3
3
5
6
Cool Stir
1
40
40
6
Cool Stir
3
4
5
7
Cool Stir
1
40
40
7
Cool Stir
3
4
6
8
Cool Stir
1
40
40
8
Cool Stir
3
4
6
Initial Drop
40
Initial Drop
40
Sensor(s)
1
Sensor(s)
3
Degrees above Target
3
Degrees above Target
3