beautypg.com

Port information that is unique to fcoe, Switch administration and fcoe – Brocade Web Tools Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 248

background image

A Web Tools license is not required, and a basic version of Web Tools is available for free. Additional
functionality may be added by obtaining the Enhanced Group Management (EGM) license.

The EGM license is required only for 8 Gbps platforms, such as the:

• Brocade Encryption Switch
• Brocade 300, 5300, and 5100 switches
• Brocade VA-40FC
• Brocade 7800

For non-8 Gbps platforms, all functionalities are available without the EGM license.

Port information that is unique to FCoE

The General tab in the Port Admin tab displays several parameters that are unique to DCB/DCE
interfaces:

Interface Mode --The interface mode vales are either None or L2 mode.
VLAN ID --The VLANs that carry traffic on the links are attached to this port.
LAG --The ID of the Link Aggregation Group (LAG), with which this port is associated. If no ID is

specified, the port is not associated with any LAG.

L2 Mode --The values are Access, Trunk, or Converged. Access mode allows only one VLAN

association, and allows only untagged frames. Trunk mode allows more than one VLAN
association, and allows tagged frames. Converged mode interface can be native (untagged or
access) in one VLAN and it could be non-native (trunk or tagged) type in more than one VLAN.

DCB Map --The name of a DCB map that was created and associated with the port.
Traffic Class Map --The name of a traffic class map that was created and associated with the port.
LLDP Status --Indicates whether LLDP is active or inactive.
LLDP Profile --The name of an LLDP profile that was created and associated with the port.
FCoE Priority Bits --Each bit represents a user priority that is associated with FCoE traffic.
Default CoS --The default Class of Service.

Switch administration and FCoE

The DCB tab on the Switch Administration window is specific to DCE and DCB configuration and
management. The DCB tab has five subtabs that are used for FCoE switch administration:

Link Aggregation
VLAN
FCoE Login Group
QoS
LLDP-DCBX

FIGURE 49 Switch Administration DCB subtabs

Port information that is unique to FCoE

248

Web Tools Administrator's Guide

53-1003169-01