Chapter 7: Specifications

CAS200 User’s Guide

102

Watlow Anafaze

Table 7.18

5Vdc Output (Power to Operate
Solid State Relays)

Table 7.19

Reference Voltage Output (Power
to Operate Bridge Circuit Sensors)

Table 7.20

Processor Serial Interface

Table 7.21

Processor Power Requirements

Parameter

Description

Voltage

5Vdc

Maximum Current

350mA

Parameter

Description

Voltage

5Vdc

Maximum Current

100mA

Parameter

Description

Type

EIA/TIA-232 3-wire or EIA/TIA-485 4-wire

Isolation

None

Baud Rate

2400, 9600 or 19200, user selectable

Error Check

BCC or CRC, user selectable

Number of Scanners

1 with EIA/TIA-232 communications; up to 32 with EIA/
TIA-485 communications, depending upon protocol

Protocol

Form of ANSI X3.28-1976 (D1, F1), compatible with
Allen Bradley PLC, full duplex, or Modbus RTU

Parameter

Description

Voltage

15-24Vdc (±3Vdc)

Maximum Current

1A