Hood Installation
Oven Power Cord Modification
Twist-Lock Plug Housing
Strain Relief Screws
#6 Blue Fork Terminal
Hood Control Cord Assembly
The Oven ON/OFF switch must be bypassed when used with an AVI Hood. To bypass the
switch, a control cord assembly must be installed from the back of the control box to the VFD box.
1. Remove the control box lid.
2. Move the Control Panel to the service position.
3. Remove the knock-out located on the lower right hand corner of the control box
back
panel.
4. Install the cord connector through the knock-out hole.
5. Insert male Molex pins on the ends of the cord into the Molex connector, following the dia-
gram below.
6. Unplug the Molex connector going to the main switch assembly located in the control box.
7. Plug the control cord assembly into the Molex connector that goes to the oven switch.
Green
White
Black
Molex Connector
Control Cord
Assembly
Molex
Connector
Cord Connector
Note: Some components removed for clarity.
Replace the straight-blade plug with a twist-lock plug. Follow the plug manufacturer’s instruc-
tions.
Black wire to Gold terminal
Green wire to Center terminal
White wire to Silver terminal