beautypg.com

Figure 52 example 2: action drop-down list – Teledyne LeCroy SAS_SATA InFusion - Users Manual User Manual

Page 67

background image

SAS InFusion User Manual

Version 2.0

LeCroy Corporation

53

Figure 52

Example 2: Action Drop-Down List

Step 7

Still in the middle column of the Event Properties dialog box,
click on Primitive to bring up a drop-down menu that lets you
choose the type of primitive to substitute for RRDY (Normal)
(Figure 52). Choose ERROR.

Step 8

Click OK to close the Action Properties dialog box.

Step 9

In the File menu, select Save Scenario to save the scenario.

Note: In this example, you set the substitution action to happen at every

occurrence of an RRDY (Normal) (as shown in the Figure, the action
is set for every occurrence). However, you can set an action to
happen at other multiples of event occurrence (for example 5, 25,
1000 and so on). You also can set the action to happen at random,
within a specified number of event occurrences.