Witch, Reen, Pening – Gilderfluke&Co 'Smart' Brick Animation Control System User Manual
Page 155: Ontinuous

Sw #4
Sw #5
Switch #6
Frame rate
OFF or ON
OFF
OFF
15 FPS
OFF or ON
ON
OFF
16 FPS
OFF or ON
OFF
ON
30 FPS
OFF
ON
ON External Clock through Blue Input
ON
ON
ON
32 FPS
The thirty-two FPS frame rate is unavailable unless the
card is using the Blue input for selecting a second show.
When external clock is selected, the frames displayed
on a heads up display will carry into the seconds every
thirty frames, no matter what rate the frames are actually
arriving at the MiniBrain.
S
WITCH
#7:
S
TOP
O
N
G
REEN
O
PENING
:
When this switch is turned on, the MiniBrain will stop
when the Green input is opened. This switch is used
when you would like the show to run AS LONG as the
Green input is closed. The MiniBrain will start playing
when the Green input is activated, and stop when the
Green input is deactivated.
S
WITCH
#8:
R
UN
C
ONTINUOUS
:
This switch works in parallel with the Green input.
When it is ON, the MiniBrain will start playing. At the end of
a show, the MiniBrain will reset back to the first frame and
continue playing from the beginning of the show. This
switch can be used to start a show playing, or if it is left
ON the MiniBrain will start playing as soon as power is
applied and will loop at the end of the show. Note that
when this switch is left ON, the Green input is disabled.
G
ILDERFLUKE
& C
O
.• 205 S
OUTH
F
LOWER
S
TREET
• B
URBANK
, C
ALIFORNIA
91502 • 818/840-9484 • 800/776-5972 •
FAX
818/840-9485
E
AST
C
OAST
/F
LORIDA
O
FFICE
• 7041 G
RAND
N
ATIONAL
D
RIVE
• S
UITE
128d • O
RLANDO
, F
L
. 32819 • 407/354-5954 •
FAX
407/354-5955
145 of 178