X” exit setup mode – Gilderfluke&Co 'Smart' Brick Animation Control System User Manual
Page 130

set. If a key has not yet expired, it will be halted at its cur-
rent count and will not expire. The Smart Brick Brain will re-
port on any key that is entered, and if the key successful-
ly unlocked or or not.
If the Smart Brick Brain has been locked, then it will ask
for a password before allowing you to enter configura-
tion mode. If the password clears the lock, and there are
no other locks set, then you will enter configuration after
you then hit ‘any’ key.
“x” eXit Setup Mode:
This command is used to exit the setup mode. It is
when you exit that the Smart Brick Brain saves the check-
sums it uses to determine if the configuration has
changed. If you power down the Smart Brick Brain with-
out exiting, the Smart Brick Brain will display a ‘CS Error’
message each time it boots. To clear this, you must enter
configuration and exit again, to allow the checksum to
be calculated.
After exiting configuration for the final time, you
should move the ‘write protect’ switch to the ‘protected’
position. This will prevent any accidental or unauthorized
changes in configuration.
If you hit this command in error, hitting an
of the setup commands which don't take effect immedi-
ately, take effect when the eXit command is entered.
This includes things like the BAUD RATE, so you will have to
change the baud rate of the terminal you are using at
this time.
For compatibility with other products which might be
on the same RS-422 serial network, this command asks
you to enter a ‘Y’ or ‘N’. This lets them know that the setup
G
ILDERFLUKE
& C
O
.• 205 S
OUTH
F
LOWER
S
TREET
• B
URBANK
, C
ALIFORNIA
91502 • 818/840-9484 • 800/776-5972 •
FAX
818/840-9485
E
AST
C
OAST
/F
LORIDA
O
FFICE
• 7041 G
RAND
N
ATIONAL
D
RIVE
• S
UITE
128d • O
RLANDO
, F
L
. 32819 • 407/354-5954 •
FAX
407/354-5955
120 of 178