FEC DSP1500 (SAN3) User Manual
Page 94

enFORCE
DSP1500 SAN Unit Operation Manual
(Rev 4)
PAGE 6-18
Chapter 6: System Operation
6.4.5 Data Number Definitions
6.4.5.1 System Parameter: Parameter Number 00
¾
Data Number
00
Load Unit
Load Unit 0: KN 1: KLBS 2: METRIC TON
¾
Data Number
01
S P
Version
This is the Unit Software Version. No changes can be made.
However, the [DATA] fields are made available for Parameter Copying.
The first two digits of the [DATA] section are for the Parameter number to
copy from and the second two digits are for the Parameter number to copy to.
See Page 6-16 for operation method.
¾
Data number
02
Preamplifier Version
This is the preamplifier version. No changes can be made.
¾
Data number
03
Functioning Version
Used for special function settings. The following values are set at the factory
depending on which configuration is required. This value should not be
changed without first consulting FEC.
SAN
Unit
(Main
Configuration):
0180
SAN
Unit
(Stand
Alone
Configuration):
0103
Item
PARAMETE
RPARM
DATA NO.
D-NO
DATA
System
00
00
Load Unit 0: KN 1: KLBS 2: METRIC TON
00
01
SP Version / Parameter Copy (cannot change version)
00
02
Amplifier Version (no change allowed)
00
03
Function Version (0103=Stand Alone / 0180=with Main)
00
04
Offset Load [KN]
00
05
Distance Compensation [mm]
00
06
No Load Current Limit 0~1023
00
07
Current Load Conversion Ratio %
00
08
Home Position Offset [mm]
00
09
Resolver Position 0~4095
Tool
Data
(No
Change)
00
10
Tool Number
00
11
Tool Calibration Load [KN]
00
12
Tool Calibration Voltage [V]
00
13
Tool Zero Load Voltage [V]
00
14~1A
In House Control Data
Tool Type
00
20
Tool Number
System
00
30
Home Position Search Timeout 0.1[sec] increments
00
31
Home Position Search Speed [mm/s]
00
32
Manual Operation Speed [mm/s]
00
33
Stroke Distance Limit [mm]
00
34
Approach Distance Limit [mm]
00
35
Home Returned Signal Output Range [mm]
00
36
Option Setting 1
00
37
Option Setting 2
00
38
Option Setting 3
00
39
Option Setting 4
Real Time
Clock
00
40
RTC Date: Year “2008” = 2008
00
41
RTC Date: Month / Day “705” = July 5th
00
42
RTC Time: Hours / Minutes “1510” = 3:10PM
00
43
RTC Time: Seconds “50” = :50