FEC DSP1500 (SAN3) User Manual
Page 22

enFORCE
DSP1500 SAN Unit Operation Manual
(Rev. 4)
PAGE 2-2
Chapter 2: Specifications
2.1 System Specifications
Power Supply Voltage
180VAC ~ 242VAC, 3 phase, 50/60Hz
Operating Conditions
Temperature
32 ~ 122°F (-0 ~ 50°C)
Humidity
20 ~ 90% (no condensation)
Storage Conditions
Temperature
32 ~ 122°F (-0 ~ 50°C)
Humidity Below
90%
(no
condensation)
Shipping Conditions
Temperature
32 ~ 122°F (-0 ~ 50°C)
Humidity Below
90%
(no
condensation)
Operating Range
Duty Cycle less than 60%
Load stop accuracy
1
DPT &
DPM Series
From 1/2 to Full
Scale Load
3σ less than 3% scatter
of target load.
From 1/4 to 1/2 of
Full Scale Load
3σ less than 4% scatter
of target load.
DPS Series
From 1/4 to Full
Scale Load
3σ less than 1.5%
scatter of target load.
Load resolution
Approx. 1/1000 of full scale load value
Load control range
25% -100% of full scale load value
Load judgment range
10% -100% of full scale load value
Distance stop accuracy
1,2
± 0.01mm (-0.0 ~ +0.02mm)
Distance display minimum unit
0.1mm (0.001mm condition limit)
Distance internal control unit
0.001mm
Load cell accuracy
± 1% (0 - full scale)
Load cell linearity
± 0.5% of Full Scale value (maximum)
Press method
Load method / distance method
Ram tip pendant allowable load
1/6 or less of tool maximum load (up to 2kN)
(With brake option)
DPS-101R3-** tool is up to 0.6KN
1) When the press is operated according to FEC specifications.
2) When load is constant.