Chapter 4: System Setup and Wiring
PRESS ADVANCED: [OUT DATA8 - PIN #32]
Outputs when the press reaches the target load or target distance for a time that is
set in [61: Load Hold Time].
If Load Hold Time is set to zero the PRESS ADVANCED signal will not turn
on.
TIMING SIGNAL: [OUT DATA9 - PIN #33] (Advance / Return Position Signal Output)
Data Numbers 50, 51, 52 and 53 of Parameters 1~32 are used to set ON and OFF
limits for the Timing Signal.
[50: Advance Position ON Distance]
[51: Advance Position OFF Distance]
[52: Return Position ON Distance]
[53: Return Position OFF Distance]
This may be useful when interfacing with other fixture processes or tooling (IE:
vacuum, clamps, etc.) or when other processes need to know when the press ram is
clear.
BANK 1: [OUT DATA10 - PIN #34] Bank 1 Input Echo Signal
Output when the BANK SELECT 1 input is high (On).
BANK 0: [OUT DATA11 - PIN #22] Bank 0 Input Echo Signal
Output when the BANK SELECT 0 input is high (On).
Í
50
53
ON
OFF
51
OFF
ON
52
0mm
150mm
Example #1
[50: 50.0mm]
[51: 120.0mm]
[52: 150.0mm]
[53: 100.0mm]
50
53
ON
OFF
150mm
Example #2
[50: 50.0mm]
[51: Max Distance]
[52: Max Distance]
[53: 100.0mm]
0mm