FEC DSP1500 (SAN3) User Manual
Page 112

enFORCE
DSP1500 SAN Unit Operation Manual
(Rev 4)
PAGE 6-36
Chapter 6: System Operation
¾
Data Number 30 - Final Distance High Limit (Methods 3, 6 and 7)
In special press methods which may be judging two different zones, this is the final target
distance high limit.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 31 - Distance Low Limit
¾
Data Number 32 - Distance High Limit
Minimum and maximum acceptable distance limits for the target distance or load.
In Load Control, if [32: Distance High Limit] is reached before achieving [14: Target
Load], the press will stop.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 33 - Target Distance
In Distance Control Methods, this is the target distance value.
(Example: If Target Distance is 100mm, press will attempt to operate until 100mm is
reached.)
A setting is possible from 0 to stroke distance limit.
¾
Data Number 34 - Judgment Load Detection Point (Method 2)
In the [Specified Point Load Judgment] method, this is the distance at which the load will
be judged. Judgment is carried out at the end of the cycle.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 35 - Approach Distance
The distance of Approach Speed operation. This distance is measured from [41: Job
Start Position], not from end of [60: Slow Start Time].
A setting is possible from 0 to approach distance limit.
¾
Data Number 37 - Press Speed 1 Start Distance
The distance at which Part Search Speed will change to Press Speed 1.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 38 - Press Speed 2 Start Distance
The distance at which Press Speed 1 will change to Press Speed 2.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 39 - Detection Start Distance (Methods 3, 4, 6 and 7)
In certain special press methods, this is the distance at which the press will begin looking
for the programmed judgment value.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 40 - Detection End Distance (Method 4)
In [Specified Range Peak Load Judgment] method, this is the distance at which the press
will stop looking for the programmed judgment value.
A setting is possible from 0 to stroke distance limit.
¾
Data Number 41 - Job Start Position
The press will go back to this position after operating when a Return Operation is set.
A setting is possible from 0 to stroke distance limit.
If a Return Operation is set and the Start signal goes low (OFF), the press will
move to this position.
Í
Distance Settings