FEC DSP1500 (SAN3) User Manual
Page 81

enFORCE
DSP1500 SAN Unit Operation Manual
PAGE 6-5 (Rev
4)
Chapter 6: System Operation
Data format when the judgment is a REJECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Cycle Count
Press
Number
Parameter
Number
30H 30H 30H 30H 30H 30H
30H
31H
20H
30H
31H
20H
20H 31H 20H 20H
0 0 0 0 0 0 0 1 0 1 1
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Judgment Load
Judg
ment
Judgment Distance
Judg
ment
31H 32H 2EH 33H 34H 48H
20H
31H
32H
33H
2EH
34H
35H 36H 4CH 20H
1 2 . 3 4 H 1 2 3 . 4 5 6 L
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Final Load
Judg
ment
Final Distance
Judg
ment
31H 32H 2EH 33H 34H 20H
20H
31H
32H
33H
2EH
34H
35H 36H 20H 20H
1 2 . 3 4 1 2 3 . 4 5 6
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
Part Check 1 Distance
Judg
ment
Part Check 2 Maximum Load
Judg
ment
31H 32H 33H 2EH 34H 35H
36H
5AH
20H
31H
32H
2EH
33H 34H 48H 20H
1 2 3 . 4 5 6 Z 1 2 . 3 4 H
65 66 67 68 69 70 71 72 73 74 75 76 77 78
Part Check 3 Maximum Load
Judg
ment
Judg
ment
Rea
son
CR LF
31H 32H 2EH 33H 34H 4CH
20H
20H
58H
20H
20H
20H
0DH 0AH
1 2 . 3 4 L X
Overall Judgment
Reason for Stop
"X"(58H):REJECT
"00000001 01 1 12.34H 123.456L 12.34 123.456 123.456Z 12.34H 12.34L X "+CR+LF
When the reject is for Final Load or Final Distance the Judgment Load and Judgment
Distance are also judged.
Н