FEC DSP1500 (SAN3) User Manual
Page 87
enFORCE
DSP1500 SAN Unit Operation Manual
PAGE 6-11 (Rev
4)
Chapter 6: System Operation
6.3.5 Press Result Display Mode
The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.
D-NO DATA UNIT
_0
Peak Load Value(Judgment Load Value) KN
_1
Final Distance Value
mm
_2
Distance Measurement Start Load distance
mm
_3
Distance at Interference Check Load
mm
_4
1
st
Zone Operating Time
Sec
_5
Final Zone Operating Time
Sec
_6
Cycle Time
Sec
_7
Press Mode Number
_8
Electronic Thermal Value at Operation End (Load Factor) [*100:”Load Over”]
_9
Last 4 digits of Final Distance
mm
-0
Last 4 digits of Distance Measurement Start Load distance
mm
-1
Absolute Final Distance
mm
-2
Last 4 digits of Absolute Final Distance
mm
-3
Self Check ON: performed OFF: not performed
-4
Speed when Part Check 1 Load was Detected
mm/sec
-5
Cause of press stop
0: Reset/No Data/After manual operation 1: Abnormal
2: BYPASS signal 3: STOP signal 4: REJECT
5: ACCEPT signal 6: START signal OFF 7: CW signal
8: CCW signal
-6
Load Judgment Ld H/L
-7
Distance Judgment dS H/L
-8
Work Check
0: Interference Check 1: Part Check 1 with High or Low Judgment
2: Part Check 2 with High or Low Judgment
3: Part Check 3 with High or Low Judgment
-9
Distance at Part Check 1 Load
mm
=0
Part Check 2 Minimum Load
KN
=1
Part Check 2 Maximum Load
KN
=2
Part Check 2 Distance at Minimum Load
mm
=3
Part Check 2 Distance at Maximum Load
mm
=4
Part Check 3 Minimum Load
KN
=5
Part Check 3 Maximum Load
KN
=6
Part Check 3 Distance at Minimum Load
mm
=7
Part Check 3 Distance at Maximum Load
mm
=8
Final Load
KN
=9
Distance at Judgment Load
mm
「
D-NO」 「DATA」
Peak load value
Final Distance value
Distance at Judgment Load
D-NO
:
Digit on the Left
0
1
9
[↑] / [↓]
buttons