PASCO EM-8656 AC_DC ELECTRONICS LABORATORY User Manual
Page 64
![background image](/manuals/340684/64/background.png)
60
AC/DC Electronics Laboratory
012-05892A
®
➄
Connect the alligator clips of the Channel B voltage sensor to the wires at both ends of the 1 k
resistor.
➅
Connect banana plug patch cords from the output of the Power Amplifier to the banana jacks on
the AC/DC Electronics Lab Board.
Part III: Data Recording - Diode and 1 k Resistor
➀
Turn on the power switch on the back of the power amplifier.
➁
Click the “ON” button (
) in the Signal Generator window.
➂
Click the “REC” button (
) to begin data recording.
•
Data recording will end automatically after 250 samples are measured. Run #1 will appear in the
Data list in the Experiment Setup window.
➃
Click the “OFF” button (
) in the Signal Generator window. Turn off the switch on the back
of the power amplifier.
ANALYZING THE DATA: Diode and 1 k
Ω
Resistor
➀
Click the “Autoscale” button (
) to resize the Graph to fit the data.
•
The vertical axis shows Current in milliamps based on a calculation using the voltage drop across
the 1 k
Ω
resistor. The horizontal axis shows Voltage across the diode.
➁
Select “Save As…” from the File menu to save your data. Select “Print Active Display” from the
File menu to print the Graph.
➂
Click the “Magnifier” button (
). The cursor changes to a magnifying glass shape.