beautypg.com

PASCO EM-8656 AC_DC ELECTRONICS LABORATORY User Manual

Page 101

background image

97

012-05892A

AC/DC Electronics Laboratory

®

11

Put alligator clips on the banana plugs of both Voltage Sensors. Connect the black alligator clip
of the Voltage Sensor in Analog Channel A to the component spring at the top end of the 22 k

resistor, and the red clip to the component spring at the bottom end.

12

Connect the red alligator clip of the Voltage Sensor in Analog Channel B to the component
spring at the top end of the 1 k

resistor, and the black clip to the component spring at the

bottom end.

PART IIIA: Data Recording – ±1.5 Volts

Turn on the DC power supply and adjust its voltage output to exactly +5 Volts.

Turn on the power switch on the back of the power amplifier.

Click the “ON” button (

) in the Signal Generator window.

Click the “REC” button (

) to begin recording data. Recording will stop automatically after

200 samples are measured.

Run #1 will appear in the Data list in the Experiment Setup window.

Click the “OFF” button (

) in the Signal Generator window.

Turn off the power switch on the back of the power amplifier. Turn off the DC power supply.