beautypg.com

Communication – Liquid Controls SP4000 User Manual

Page 86

background image

83

SP4000 Flow Computer

PRINT INITIATE

DATALOG ONLY

PRINT INTERVAL

PRINT TIME

DATALOG FORMAT

2

RATE

1

TOTAL

2

RATE

1

TOTAL

COMMUNICATION

6.13

COMMUNICATION
(Continued)

Datalogger and/or printing variables and parameters over the serial
RS-232 interface can be initiated at regular intervals (INTERVAL) or
daily at a fixed time (TIME OF DAY) or by front key depression.

Note:
Printing can always be initiated by pressing the PRINT key.

Selection:

NONE, TIME OF DAY, INTERVAL, ENABLE PRINT KEY

Display:

TIME OF DAY
PRINT INITIATE

Select YES or NO for Datalog Only prompt.

Selection:

YES - Data is logged but no information is sent on print event.
NO - Data is logged and immediately transmitted.

Display:

YES
DATALOG ONLY

Define a time interval. Variables and parameters will be periodically
logged at regular intervals of this value of time. The setting "00:00"
deactivates this feature.

Input:

Time value in hours & minutes (HH:MM).

Display:

00:00
PRINT INTERVAL

Define the time of day that variables and parameters will be logged
out daily.

Input:

Time of day in hours & minutes (HH:MM).

Display:

00:00
PRINT TIME

Define the Datalog Format.

Selection:

DATABASE -

Data sets sent in comma seperated variable
format.

PRINTER -

Individual output variables sent with text
label and units suitable for printing.

Display:

PRINTER
DATALOG FORMAT