SP4000 Flow Computer

3.5 Liquid Mass

Measurements:
Actual volume flow is measured by the flowmeter. Temperature is measured by the
temperature transmitter. A pressure transmitter can be used to monitor pressure. Pressure
measurement does not affect the calculation. A density transmitter may be used in place
of a temperature transmitter for direct density measurement.

Calculations:
• The density and mass flow are calculated using the reference density and the thermal

expansion coefficient of the liquid (see "FLUID DATA" submenu)

Output Results:
• Display Results

Mass or Volume Flow Rate, Resettable Total, Non-Resettable Total,
Temperature, Pressure, Density (optional: peak demand, demand last hour,
time/date stamp)

• Analog Output

Mass or Volume Flow Rate, Temperature, Pressure, Density, Peak Demand,
Demand Last Hour

• Pulse Output

Mass or Volume Total

• Relay Outputs

Mass or Volume Flow Rate, Total, Temperature, Pressure, Density Alarms,
Peak Demand, Demand Last Hour

Applications:
Monitoring mass flow and total of any liquid. Flow alarms are provided via relays and
datalogging is available via analog (4-20mA) and serial outputs.

Liquid Mass

Liquid Mass
Illustration

Volume Flow

As calculated in section 3.4

Mass Flow

Mass Flow = volume flow • (1-a • (T

1

-T

ref

))

2

• ref. density

α

= Thermal expansion coefficient • 10

-6

Calculations

NOTE:
A density transmitter may be used
for direct density measurement.