SP4000 Flow Computer

DISPLAY

6.5
DISPLAY

Select the variable that are to be displayed in the "HOME position"
during normal operation. Each variable can be assigned to line 1
(L1), line 2 (L2) or NO (removed from scroll list).

Note:

• To initiate the scroll list press the SCROLL key. The list will

be displayed in groups of two, each group is displayed for
approximately 3 to 4 seconds.

• Any alarm messages will be displayed periodically,

alternating throughout the scroll list.

Selection (with Prompt):

CHANGE? YES, NO

ADD TO LIST? L1, L2, NO

Variable Selection:

HEAT FLOW, MASS FLOW, VOLUME FLOW, STD.
VOLUME FLOW, TEMP.1, TEMP.2, DELTA T, PRESSURE,
DENSITY, SPEC. ENTHALPY, TIME, DATE, HEAT TOTAL,
HEAT GRAND TOTAL, MASS TOTAL, MASS GRAND
TOTAL, STD VOLUME TOTAL, STD.V. GRAND TOTAL,
VOLUME TOTAL, VOL. GRAND TOTAL, PEAK DEMAND,
DEMAND LAST HOUR, PEAK DEMAND TIME, PEAK
DEMAND DATE

Note: Variable selection will vary depending on Flow Equation

selected and options supplied.

Display:

ADD TO LIST? L1
HEAT FLOW?

SCROLL LIST