SP4000 Flow Computer

EZ SETUP

2

RATE

1

TOTAL

6.2
EZ
SETUP
(Continued)

FULL SCALE VALUE
(PRESSURE)

DEFAULT VALUE
(PRESSURE)

2

RATE

1

TOTAL

2

RATE

1

TOTAL

INPUT SIGNAL
(PRESSURE)

Select the appropriate pressure input signal.

Selection:

MANUAL PRESSURE, 4-20 PRESSURE (ABS.), 0-20
PRESSURE (ABS.), 4-20 PRESSURE (G), 0-20
PRESSURE (G)

Display:

4-20 PRESSURE (ABS.)

INPUT SIGNAL

Enter the full scale value for the pressure input signal.

Input:

Number with fixed decimal point:
000.000 ... 999.999

Display:

580.000 psia

FULL SCALE VALUE

Enter the default value for the pressure input signal.

Input:

Number with fixed decimal point:
000.000 ... 999.999

Display:

14.696 psia

DEFAULT VALUE

NOTE: After the last entry has been saved, the display automatically

returns to the HOME position. The “EZ Setup” routine is
completed and the flow computations are resumed.