SP4000 Flow Computer
FLOW INPUT
Set the full scale value for the analog input signal.
The value entered here must be identical to the value set for the
flowmeter.
Note:
• For flowmeters with analog/linear output, Target, generic
square law and Gilflo flowmeters, the flow computer uses
the selected system units for volumetric flowrate.
• The units for differential pressure flowmeters are
dependent on the system units selected for pressure:
- Imperial units [inches H2O]
- Metric units: [mbar]
Input:
Number with floating decimal point: 0.000...999999
Display:
10000.00 ft3/h
FULL SCALE VALUE
Set the low scale value for the high range transmitter analog input
signal.
The value entered here must be identical to the value set for the
flowmeter.
Note:
• The units for differential pressure flowmeters are
dependent on the system units selected for pressure:
- Imperial units [inches H2O]
- Metric units: [mbar]
Input:
Number with floating decimal point: 0.000...999999
Display:
.000 ft3/h
LOW SCALE-HIGH RANGE
Set the full scale value for the high range transmitter analog input
signal.
The value entered here must be identical to the value set for the
flowmeter.
Note:
• The units for differential pressure flowmeters are
dependent on the system units selected for pressure:
- Imperial units [inches H2O]
- Metric units: [mbar]
Input:
Number with floating decimal point: 0.000...999999
Display:
10000.00 ft3/h
FULL SCALE VALUE
FULL SCALE
LOW SCALE-HI
RANGE
FULL SCALE-HI
RANGE