System units – Liquid Controls SP4000 User Manual
Page 52

49
SP4000 Flow Computer
SYSTEM UNITS
6.6
SYSTEM
UNITS
(Continued)
Select the unit for process pressure.
Note:
The unit selected here also applies to the following:
• Zero and full scale value for current
• Relay setpoints
• Reference conditions
Differential pressure is in mbar for Metric selections
Differential pressure is in "H
2
O f or English selections
Selection:
bara, kpaa, kc2a, psia, barg, psig, kpag, kc2g
Definitions:
bara
bar
kpaa
kpa
Absolute pressure
kc2a
kg/cm
2
("a" for absolute)
psia
psi
barg
bar
Gauge pressure compared to
kpag
kpa
atmospheric pressure
kc2g
kg/cm
2
("g" for gauge)
psig
psi
Gauge pressure differs from absolute pressure by the
atmospheric pressure, which can be set in the submenu
group "OTHER INPUT".
Display:
psia
PRESSURE UNIT
Select the unit for the density of the fluid.
Note:
The unit selected here also applies to the following:
• Zero and full scale value for current
• Relay setpoints
Selection:
kg/m
3
, kg/dm
3
, #/gal, #/ft
3
(# = lbs = 0.4536 kg)
Display:
#/ft3
DENSITY UNIT
PRESSURE UNIT
DENSITY UNIT
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)