beautypg.com

Delivery status – Liquid Controls DMS Setup User Manual

Page 62

background image

62

Screen 23a, b, c, d: Delivery Status (1/4, 2/4, 3/4, 4/4)

Delivery Status

The Delivery Status and Delivery Code screens contain

information relative to the delivery.
ROM Check Sum indicates if a delivery could not be

started due to the checksum of the LectroCount program

code space failing.
Temperature indicates if the currently delivery was not

started or was terminated due to an error detected with

the temperature reading hardware.
Watchdog indicates if the processor was reset due to a

LectroCount watchdog timeout error.
VCF Setup indicates if there was an error setting up the

volume compensation factor for the current product.
VCF Domain indicates if the temperature of the product

being delivered is outside the valid range for the

compensation type of the product.
Meter Calibration indicates if an error occurred while

setting up the meter calibration for the current delivery.
Pulser Failure indicates if the current delivery was

terminated due to too many pulser faults.
Preset Stop indicates if a gross or net preset volume has

been reached.
No-Flow Stop indicates if the current delivery was

stopped due to no flow being detected through the meter

for a specified amount of time.
Stop/Pause Request indicates if the STOP/PAUSE Key

was pressed on the keypad during an active delivery.
Print/End Request indicates if the PRINT/END Key on

the keypad was pressed during an active delivery.
Power Failure indicates a delivery ended due to a power

fail condition for more than 15 seconds.
Preset Error indicates if a delivery ended due to an

error condition while attempting to set up a gross or net

preset.
RS-232 Lap Pad indicates if the RS-232 Lap Pad has

been disconnected from the LectroCount during an active

delivery.
Printer indicates if the current delivery requires a ticket to

be printed and the printer is either off-line or busy.
Data Access indicates if a data access error occurred

during a delivery which was critical to the delivery.

(1/4) 1

No

No

No

No

DELIVERY STATUS
ROM Check Sum?

Temperature?

Watchdog?

VCF Setup?

Next Status

(2/4) 1

No

No

No

No

DELIVERY STATUS
VCF Domain?

Meter Calibration?

Pulser Failure?

Preset Stop?

Next Prev Status

(3/4) 1

No

No

No

No

DELIVERY STATUS
No-Flow Stop?

Stop/Pause Request?

Print/End Request?

Power Failure?

Next Prev Status

(4/4) 1

No

No

No

No

DELIVERY STATUS
Preset Error?

RS-232 Lap Pad?

Printer?

Data Access?

Prev Status