Save configuration, Screen 14: save configuration – Liquid Controls DMS Setup User Manual

Page 51

background image

51

Save Configuration

Screen 14: Save Configuration

This feature allows the user of LCRHost to save

the calibration and configuration parameters of an

LectroCount in a file. This file can then be used to set up

other LectroCount registers with same data without having

to manually enter data individually.
Press

ENTER to open a field edit window and enter an

alphanumeric

Output File name up to 15 characters in

length. When complete, press

Save (F1) to save output

file. When

Save (F1) is pressed, system will prompt the

operator with the list box window that asks if the current

file should be overwritten with the selected

Output File.

Select

Yes or No and press ENTER.

The fields saved in the output file are:

DateFormat

Decimals

FlowDirection

MeterID

NoFlowTimer

Odometer

PresetsAllowed

PresetType

Printer

PrintGrossAndParam

PulseOutputEdge

PulsesPerDistance

QtyUnits

Residual

SaleNumber

TempScale

TicketNumber

TicketRequired

TimeUnit

UnitID

VolCorrecteDMS i1000g

For each of the four

product calibrations:

Aux1

Aux2

AuxMult

AuxUnit

BaseTemp

CompensationParam

CompensationType

GrossPreset

GrossTotal

Linearize

NetPreset

NetTotal

PercentTax

PricePerUnit

ProductCode

ProductDescriptor

ProductType

PulsesPerUnit

S1Close

TaxPerUnit

For each of the 10

linearization points:

LinearFlowRate

LinearError

For each of the 12 ticket

header lines:

TicketHeaderLine

Press

Main (F5) to return to Screen 2 on page 20. Move

pointer to

Load Configuration and press ENTER to

advance display to

Screen 18 on page 52.

1

SAVE CONFIGURATION

Use the field below to specify

the output file that will

receive the configuration data

from the LCR.
Output File:

Save LCR# Main