Screen 8b: General Setup (2/5)

Sale # is used to track number of transactions LectroCount

processes. This number will increment each time a

delivery is started.
Press

ENTER to open a field edit window to enter starting

number for

Sale # and press ENTER to accept. The

LectroCount will use this as the starting value for

Sale #

and increment by 1 each time a delivery is started. Once

a

Sale # reaches 999999, it will return the count to zero

and resume counting from

1.

Ticket # is similar to Sale # however, Ticket # will

increment each time LectroCount prints a ticket.

If multiple or duplicate tickets are used for transactions,

the ticket number will increment more than the

Sale #.

Press

ENTER to open a field edit window and enter

starting number for

Ticket # and press ENTER to accept.

LectroCount will use this as the starting value for

Ticket #

and increment by 1 each time a delivery ticket is printed.

Once

Ticket # reaches 999999, it will return the count to

one and resume counting from

1.

NOTE: If 0 is entered for Ticket #, the Ticket # will not

print on the delivery ticket and it will not increment.
Print Gross & Param? is used to enable or disable

printing of gross volume and compensation parameter

on the delivery ticket if the product is temperature

compensated. In many applications this is required.

Check local Weights & Measures requirements.
Press

ENTER to open a list box window. Select No if it is

NOT desired to print the gross volume and compensation

parameter on the ticket. Select

Yes if it IS desired to

print the gross volume and compensation parameter on

the ticket.
Volume Corrected Message? is used to enable or disable

printing of the base temperature of net deliveries on the

delivery ticket. In many applications, this is required.

Check local Weights & Measurements requirements.

There are two options for

Vol Corrected Msg?. Select

No if the volume corrected message is NOT printed on the

delivery ticket. Select

Yes to have the volume corrected

message printed on the delivery ticket. If

Yes is selected,

the LectroCount will print a message on the delivery ticket

indicating the delivery volume has been corrected to a

specified base temperature.
If base temperature is in °C, the message will read:

TEMPERATURE VOLUME CORRECTED TO 15 °C
If the base temperature is in °F, the message will read:

TEMPERATURE VOLUME CORRECTED TO 60 °F
NOTE
: The base temperature for Linear C and Linear F

can be set to a value other than their default values.
All LectroCount registers feature a calibrated pulse output

which cycles once per least significant unit of delivery.

The

Pulse Out Edge field allows the LectroCount to

synchronize the calibrated pulse output waveform with the

requirements of an external counter. Depending on the

manufacturer, some counters may increment on the rising

pulse edge of the waveform, some on the falling pulse

edge. Refer to the manufacturer’s manual to determine

the specific requirements.
The List Box Window has two options. Select

Rising for

the rising edge of the pulse output. Select

Falling for the

falling edge of the pulse output.
Press

Next (F1) to advance to Screen 8c on page 31.

General Setup

(2/5) 1

1

1

Yes

Yes

Falling

GENERAL SETUP

Sale #:

Ticket #:

Print Gross & Parameter?

Volume Corrected Message?

Pulse Output Edge:

Next Prev Cnfg Main