General setup, Screen 8b: general setup (2/5) – Liquid Controls DMS Setup User Manual
Page 30

30
Screen 8b: General Setup (2/5)
Sale # is used to track number of transactions LectroCount
processes. This number will increment each time a
delivery is started.
Press
ENTER to open a field edit window to enter starting
number for
Sale # and press ENTER to accept. The
LectroCount will use this as the starting value for
Sale #
and increment by 1 each time a delivery is started. Once
a
Sale # reaches 999999, it will return the count to zero
and resume counting from
1.
Ticket # is similar to Sale # however, Ticket # will
increment each time LectroCount prints a ticket.
If multiple or duplicate tickets are used for transactions,
the ticket number will increment more than the
Sale #.
Press
ENTER to open a field edit window and enter
starting number for
Ticket # and press ENTER to accept.
LectroCount will use this as the starting value for
Ticket #
and increment by 1 each time a delivery ticket is printed.
Once
Ticket # reaches 999999, it will return the count to
one and resume counting from
1.
NOTE: If 0 is entered for Ticket #, the Ticket # will not
print on the delivery ticket and it will not increment.
Print Gross & Param? is used to enable or disable
printing of gross volume and compensation parameter
on the delivery ticket if the product is temperature
compensated. In many applications this is required.
Check local Weights & Measures requirements.
Press
ENTER to open a list box window. Select No if it is
NOT desired to print the gross volume and compensation
parameter on the ticket. Select
Yes if it IS desired to
print the gross volume and compensation parameter on
the ticket.
Volume Corrected Message? is used to enable or disable
printing of the base temperature of net deliveries on the
delivery ticket. In many applications, this is required.
Check local Weights & Measurements requirements.
There are two options for
Vol Corrected Msg?. Select
No if the volume corrected message is NOT printed on the
delivery ticket. Select
Yes to have the volume corrected
message printed on the delivery ticket. If
Yes is selected,
the LectroCount will print a message on the delivery ticket
indicating the delivery volume has been corrected to a
specified base temperature.
If base temperature is in °C, the message will read:
TEMPERATURE VOLUME CORRECTED TO 15 °C
If the base temperature is in °F, the message will read:
TEMPERATURE VOLUME CORRECTED TO 60 °F
NOTE: The base temperature for Linear C and Linear F
can be set to a value other than their default values.
All LectroCount registers feature a calibrated pulse output
which cycles once per least significant unit of delivery.
The
Pulse Out Edge field allows the LectroCount to
synchronize the calibrated pulse output waveform with the
requirements of an external counter. Depending on the
manufacturer, some counters may increment on the rising
pulse edge of the waveform, some on the falling pulse
edge. Refer to the manufacturer’s manual to determine
the specific requirements.
The List Box Window has two options. Select
Rising for
the rising edge of the pulse output. Select
Falling for the
falling edge of the pulse output.
Press
Next (F1) to advance to Screen 8c on page 31.