75

Operatingandfunctions

9.7

Details of the parameters menu

To access the Parameters menu, simultaneously press keys

ENTER

for at least 5

s.

This menu comprises the following configurable parameters:

LANGUAGE

UNit

K-FACtOR

OPtiONAL

OVERFiLL

ALARM

OUtPUt

BACKLit

END

0......9

SAVE N/Y

Process level

RESEt

Choosing the display language

Choosing the dosing units, the flow rate units, the units and number of decimals of the
volume or mass totalizers

Entering the K factor of the fitting used or having it defined through a teach-in
procedure.

Configuring the outputs (DO1 to DO4).

Resetting the 2 volume or mass totalizers and/or the 2 totalizers of the done dosings
and/or the History menu.

Setting the brightness of the display and how long it stays ON, or deactivating the
backlight.

Saving or not the changes made within the Param-
eters menu.

If the changes are saved, the device operates with
the new settings.

• Choosing the dosing mode among 8 possible modes.

• Entering up to 7 dosing quantities, V1 to V7.

• Deactivating the overfill correction.

• Activating the overfill correction and choosing its operating mode among 4 possible

operatings.

• Deactivating the generation of alarms for problems occuring during a dosing and/or

once the dosing is finished.

• Activating the generation of alarms for problems occuring during a dosing and/or

once the dosing is finished, and entering the time delays before generation.

Figure 54:

Diagram of the Parameters menu

English

Type 8025 - 8035 BATCH