2 mechanical data, Mechanical data – Burkert Type 8035 User Manual
Page 16
14
Technicaldata
Fluid temperature, compact version
• 8025, compact version
• 8035
The fluid temperature may be restricted by the fluid
pressure and the materials the fitting used is made
of. See “Figure 7”, chap. “7.2.1” or “Figure 14”, chap.
“7.5”.
• -15 to +80 °C
• -15 to +100 °C
Fluid pressure, compact version
• 8025, compact version
• 8035
The fluid pressure may be restricted by the fluid
temperature and the materials the fitting used is made
of. See “Figure 7”, chap. “7.2.1” or “Figure 14”, chap.
“7.5”.
• PN10
• PN10 or PN16
Flow rate measurement, compact version
• Measurement range
• measurement error, with a K factor Teach-In procedure
• Measurement error, with K factor of the fitting used
• Linearity
• Repeatability
• 0,3 to 10 m/s
• ±0,5 % of the full scale
1)
• ±(0,5 % of the full scale + 2.5 % of the measured
value)
1)
• ±0,5 % of the full scale
1)
• ±0,4 % of the measured value
1)
Determined in the following reference conditions: fluid = water, water and ambiant temperatures = 20 °C, upstream and
downstream distances respected, appropriate pipe dimensions.
6.3.2
mechanical data
part
material
Housing and cover with lid, compact version
PC, lid with UV filter
Housing and cover, wall-mounted version
ABS
Cable glands, compact or wall-mounted versions
PA
Open housing, panel-mounted version
PC
Foil
Polyester
4 screws
Stainless steel
Flow sensor holder, 8025 compact version
PVDF
Axis and bearing of the paddle-wheel, 8025 compact
version
ceramics
Paddle wheel, 8025 compact version
PVDF
O-ring seal, 8025 compact version
FKM (or EPDM, delivered with the device)
Nut, 8025 compact version
PC
Specifications of the fitting
refer to the related operating instructions
Cable clips
PA
English
Type 8025 - 8035 BATCH