beautypg.com

5 electrical connection, Versions), Electrical connection – Burkert Type 8035 User Manual

Page 21

background image

19

Technicaldata

Digital inputs Di1 to Di4

• commutation threshold V

on

• commutation threshold V

off

max.

• min. pulse duration

• input impedance

• protection

• 5 to 36 V DC

• 2 V DC

• 100 ms

• 9,4 kW

• galvanically isolated, and protected against polarity

reversals and voltage spikes

6.3.4

specifications of the connected flow sensor (panel-
mounted and wall-mounted versions)

Signal originating from the remote
sensor

• type

• frequency

• max. voltage

• pulse, sine-wave (typical sensitivity 50 mV peak-to-peak at 250 Hz),

"on/off", or standard voltage 0-5 V DC

• 0,6 Hz to 2,2 kHz, can be adjusted

• 36 V DC

Input impedance

depends on the position of selector "LOAD" on the electronic board of
the 8025.
See chap. “7.6.4” and “7.6.7”.

Power supply, if the dosing controller is
energized with a 12-36 V DC voltage

supplied by the dosing controller depending on the position of
selector "SENSOR SUPPLY" of the 8025, either:

• 5 V DC, 30 mA max.

• (L+)-12V: supply voltage (L+) of the dosing controller minus

12 V DC (minus 12,5 V DC max.), 80 mA max.

• L+: supply voltage (L+) of the dosing controller (minus 1,5 V DC

max.), 140 mA max.

Power supply, if the dosing controller is
energized with a 115/230 V AC voltage

supplied by the dosing controller depending on the position of
selector "SENSOR SUPPLY" of the 8025, either:

• 5 V DC, 30 mA max.

• (L+)-12V: 27 V DC minus 12 V DC (minus 12,5 V DC max.), 80 mA

max.

• L+: 27 V DC, 80 mA max.

6.3.5

electrical connection

Type of connection

on the terminal blocks of the electronics (and through
cable glands for the compact and wall-mounted
versions)

English

Type 8025 - 8035 BATCH

This manual is related to the following products: