74

Operatingandfunctions

8.5 %

The device shows the percentage of the quantity that has been
already dosed (symbol % blinks).

To read the flow rate measured in the pipe, press

or

0......9

.

To read the total dosing quantity, press

or

0......9

once.

To interrupt the dosing, see “Figure 53”.

Confirm.

BAtCH R.

OK Y/N

Choose "OK Y" to start a new dosing.

Confirm.

Process level

100.4 %

When the dosing is finished:

• the display shows the reached percentage (about 100%),

• and the valves are closed.

To go back to the Process level in order to start a new dosing,
press

ENTER

.

Figure 52:

Doing a dosing, in dosing mode "LOC. REP."

To interrupt the dosing, press

ENTER

: the valve connected to output DO2 and possibly the valve connected

to output DO3 close, the device state LED flashes at a 1 Hz-frequency and the DO4 output (if configured to
transmit the device state, see chap. “9.7.26”) generates a 1 Hz-frequency.

CONtiNUE

0......9

RESEt

Confirm to continue the dosing.

Confirm to abort the dosing. The device goes back to the Process level.

10.2 %

The counting of the dosing quantity continues.

BAtCH R.

The device is ready for a new dosing.

Figure 53:

Interrupting the dosing, in dosing mode "LOC. REP."

English

Type 8025 - 8035 BATCH