3 terminal assignment and use of the selectors, Terminal assignment and use of the selectors, English – Burkert Type 8035 User Manual
Page 33: 31 installationandwiring
31
Installationandwiring
7.6.3
Terminal assignment and use of the selectors
2
A
1
5
B
C
6
CURRENT
SOURCE
SINK
BINARY
PE
PE
PE
PE
DI1
DI2
DI3
DI4
DO4
ISOG
FLOW
SENSOR
L+
L-
PE P- P+
NC
Iout
PULSE
DO1
Supply
12..36Vdc
Univ
Batch
(AO1)
SUPPLY
NC
COIL
PULSE INPUT
NPN/PN
P
2
1
3
PE
+
-
SENSOR
SUPPL
Y
LOAD
+5V
L+
(L+)-12V
COIL/PNP
39K
470
2.2K
SENSOR TYPE
COIL
NPN/PNP
DO2
DO3
OF
FO
N
3
4
terminal block 1
• NC: not connected
• L+: V+ (positive voltage)
• L-: 0V (power supply ground)
• PE: protective earth, factory wired
• P-: negative transistor output (DO1)
• P+: positive transistor output (DO1)
terminal block 2
PE: shieldings of the power supply cable and the
input / output cables
terminal block 3: wiring the DO2 relay output.
terminal block 4: wiring the DO3 relay output.
connector 5: connection of the flow sensor
terminal block 6 "binAry"
• DI1 to DI4: 4 digital inputs
• DO4: transistor output
• ISOG: ISOGND, ground common to the 4
digital inputs and the transistor output DO4.
• PE: cable shielding
selector A : see chap. “7.6.4”.
selector B : see chap. “7.6.4”.
selector C : see chap. “7.6.4”.
Figure 18:
Terminal assignment of a 12-36 V DC fed compact version
English
Type 8025 - 8035 BATCH