Table 12) – Burkert Type 8035 User Manual
Page 111
109
Operatingandfunctions
VALiD Y/N
→
To exit the function, confirm "VALID N".
→
To restore the default configuration of the device, confirm
"VALID Y".
FACt. SEt
REtURN
CONFiG.
Figure 99:
Restoring the default configuration of the device
Table 12:
Default configuration of the device
Function
Default value
LANGUAGE
English
Dosing UNITS
litre
UNIT of the flow rate
l/s
UNIT of the totalizers
litre, 0 decimals
K FACTOR
1.00
OPTIONAL
dosing mode "LOC. MANU"
V1 to V7=0.00
Parameters A and B for dosing mode "EXT. [T]"
0
Teach-In dosing quantity for dosing modes "EXT. REP."
and "LOC. REP."
0
OVERFILL CORRECTION
yes, direct, tolerance 0
ALARME during dosing
no
Time delay = 1s
ALARME at the end of the dosing
no
Time delay = 1s
OUTPUT DO1
Pulse, PU=0.0
Litre
OUTPUT DO2
Valve 100%, not inverted, time delay before opening =
0 s
OUTPUT DO3
Alarm, not inverted
OUTPUT DO4
State
ERR10Hz inactive
BACKLIGHT
level 9, activated for 30s
FLOW-WARNING
W- = W+ = 0.000
Time delay = 1s
VOLUME-WARNING
0
BATCH-WARNING
0
→
If you do not want to adjust another parameter, confirm the "END" parameter to save the settings or not and
go back to the Process level.
English
Type 8025 - 8035 BATCH