Check the slide rails

1 Run the conveyor.

Irregular movement of the chain or noise may be

caused by damaged slide rail (E).

2 If you suspect damage, try to detect deformations

of the slide rail. (only necessary on the upper side

of the conveyor).

3 If slide rail has to be replaced, see “Replacement

of slide rail” on page 28.

Check wear or damage of guides in drive unit

1 Run the conveyor and check the guides (D).

Noise from the drive unit may be caused by

damage or wear of the guides.

2 If any guides have to be replaced, find spare part

kit in separate Spare Parts documentation

.

Check motor temperature

1 Measure the motor temperature.
2 Operation temperature > approx. 70ºC indicates

overload of conveyor. Check pallet weights and

queues and compare with system specifications.

Other observations

Use “Trouble shooting” on page 62.

Cleaning conveyor chain

Only warm water (50ºC), with soap if necessary, may

be used for cleaning conveyor chains.

Other mounting instructions

“Replace motor on XT

conveyor drive unit – Side

mounted” on page 32

“Replace motor on XT

conveyor drive unit –

Centre mounted” on

page 33

Spare parts

To find correct spare parts, see separate Spare Parts

documentation.

E

E

D

Measure temperature