Lift and locate stations xtpx p12, Recommended inspection interval, Check wear of guide pins – FlexLink XT (макс. 30 кг) Тех. обслуживание User Manual
Page 12: 1 examine the guide pins (a), Check docking of pallet, Check speed of lift and lowering movement, 1 run the unit with loaded pallets, Other observations, Spare parts

2002-12-11
12
Lift and locate stations XTPX P12
Recommended inspection interval
Inspection is recommended every 1500 operating
hours or every 3rd month depending on which case
that occurs first.
Check wear of guide pins
1 Examine the guide pins (A).
2 If the guide pins have to be replaced see “Mount-
ing guide pins to locating, lift-and-rotate and lift-
and-locate station” on page 59.
Check docking of pallet
1 Run the unit and check that the pins enter the
pallet bushings in a smooth way without jam and
noise.
Check speed of lift and lowering movement
1 Run the unit with loaded pallets.
2 If necessary, adjust the throttle valves (B) on the
cylinder units.
Other observations
Use “Trouble shooting” on page 62.
Spare parts
To find correct spare parts, see separate Spare Parts
documentation.
A
B: Lift
B: Lowering