XT Conveyor XTUC _51/52
Symptom
Possible cause
Action
Reference
If fault remains
Jerky movment
Noisy
Worn or damaged
conveyor links
Replace links or
chain
“Check wear or
damage of conveyor
chain” on page 8
Contact your local
FlexLink supplier
Conveyor chain too
loose
Shorten conveyor
chain
“Check tension of
conveyor chain” on
page 8
Damaged or
deformed slide rail
Replace slide rail
“Check the slide
rails” on page 9
Worn infeed guides Replace infeed
guides
“Check wear or
damage of guides in
drive unit” on page 9
Drive motor
overheated
Drive unit infirm
Overloaded
conveyor
Remove load and
test run.
Check the
recomended load for
the conveyor.
Damaged motor
Replace motor
“Replace motor on
XT conveyor drive
unit – Side mounted”
on page 32 or
“Replace motor on
XT conveyor drive
unit – Centre
mounted” on
page 33
Incorrectly
connected electrical
cables
Check wiring
diagram
See separate
enclosed SEW
wiring diagram
Brake (only valid for
drive unit HM) not
correctly connected
Check wiring
diagram
See separate
enclosed SEW
wiring diagram