Totalizer page – Dynasonics DXN Portable Ultrasonic Measurement System User Manual
Page 56

Transmission Mode [The Type of Ultrasonic Signal The Transmitter Generates]
The Transmission Mode can be any of the following:
•
Hybrid – The DXN monitors the fluid conditions and determines automatically when to switch between Doppler and
transit time modes.
•
Transit Time – The DXN always operates in transit time mode.
•
Doppler – The DXN always operates in Doppler mode.
Totalizer Page
Site Name
0.00 GPM
1/16/2013
2:18 PM
Meter
Display
Adv
Cal
System
Site
Log
I/O
Filter
Energy
Limit
Flow
Totalizer
Total Units
Gallons
Reset Totalizer
Check To Unlock Total Reset
Figure 72: Totalizer Setups
Total Units – Totalizer Units
Gallons
Pounds
Liters
Kilograms
Mega Gallons
British Thermal Units
Cubic Feet
Thousands of BTUs
Cubic Meters
Millions of BTUs
Acre Feet
Tons
Oil Barrels
(42 Gallons)
Kilojoule
Liquid Barrels
(31.5 Gallons)
Kilowatt
Feet
Megawatt
Meters
Table 14: Totalizer Units
Select a desired engineering unit for flow accumulator (totalizer) measurements.
DXN Portable Ultrasonic Measurement System
Page 56