beautypg.com

Datamax-O'Neil DPL Programmer’s Manual User Manual

Page 94

background image

Extended System-Level Command Functions

86

(Sl) Security Lock – This command provides the ability to password-protect the
User Interface, as follows:

Value

Security Function

Nxxxx

Where xxxx is the current password, this disables Menu protection.

Yxxxx

Where xxxx is a new password, this enables Menu protection and sets a new

password.

Txxxx

Where xxxx is a new password, this enables Menu protection, disables Test
functions, and sets a new password.

To be activated, the default password (0000) must be changed.




(SL) Stop Location – This command sets the label stopping (and in certain cases

the starting) location, as follows:

Value

Stop Location

A

Automatically sets the stop location. Installed options will be “auto-sensed”

and the appropriate stop position will automatically be set. Host commands

are ignored.

H

Sets stop position according to options installed. If no options are installed the

printer sets stop location to the next label’s start of print. Host commands will

override. The stop location (present distance) may be controlled dynamically
by the host using the f or Kf commands. This selection has the
same effect as KD Ignore Host Distance bit value 0.

P

Sets the stop location at approximately two millimeters behind the peel bar
edge, a nominal peel position. The Present Sensor status and this setting are

independent.

C

Sets the stop location to a nominal cut position. For die-cut media, the

position is just following the end of the label. The cutter status and this setting
are independent.

T

Sets the stop location at the tear bar.

N

Sets the stop location to the start of the next label, equivalent to setting the
KD

Ignore Host Distance bit value 1.

This manual is related to the following products: