Extended System-Level Command Functions
60
(CU) Configuration Upgrade Package Parameters – This command allows an
upgrade package to be created.
Syntax:
1
,vvvv
1
:nnn
2
,vvvv
2
:…,nnn
n
,vvvv
n
:];
Where:
nnn
i
,vvvv
i
:
Configuration Item – Value pairs
nnn
i
Decimal Item Numbers from 1 to 9999
,
Decimal Item Number Delimiter
vvvv
i
Item Value (syntax defined later)
:
Item Value Delimitermimitd
Example – Discoverable on, service name is “smartchoice”, Bluetooth name is
“bestprinter”.
Configuration Upgrade Package parameters are defined by the following table:
Item
Number
Name
Available
to User
(Y/N)
Value Type
Description
1 Wireless
Upgrade
Type
Y Unsigned
short
1-TFTP
2-Avalanche Wavelink
3-MSP
255 – Disable
2
Configuration File
Y
String
Configuration file name (*.cfg)
for an Upgrade Package, 256
chars max.
3
TFTP IP address
Y
String
IP address of TFTP server.
4
TFTP Port
Y
Unsigned short
Port Number of TFTP Server,
default 69
5 Upgrade
Package
Version
Y
String
Read only.
6 Wireless
Upgrade
Beeper
Y
Char
0: Off; 1: On (Default).
(DE) DPI Emulation – This command allows printers with higher resolutions to
emulate lower print resolutions, as follows:
•
600 DPI can emulate 300 and 203 DPI resolutions; and,
•
400 DPI can emulate a 203 DPI resolution; and,
•
300 DPI can emulate a 152 DPI resolution.
(DK) Darkness – This command adjusts the length of the print head strobe to fine-