Extended System-Level Command Functions

82

(RI) RFID Configuration – This command configures the optional RFID interface module, as follows:

Value

Units / Interpretation

RFID Configuration Definition / Function

AIhh

where hh:

2-Chararacter Hex ID

Sets the Application Family Identifier (AFI), HF only.

ALn

and where n:

E = Enable,

D = Disable

Allows locking the AFI after writing (HF only).

Bn

where n:

D = Disable

Disables padding or truncating of data (EPC only).

Nulls are represented as “00”.
For Hex EPC data a 96-bit tag size is 24 characters and 64-bit is 16.
For ASCII EPC data a 96-bit tag size is 12 characters and 64-bit is 8.

1 = Leading

If the data is less than the selected EPC tag data size, nulls will be added to the

front (left); or, if too much data is given, the data will be cut.

2 = Trailing

If the data is less than the selected EPC tag data size, nulls will be added to the

back (right); or, if too much data is given, the data will be cut.

DIhh

where hh:

2-Chararacter Hex ID

Sets the Data Storage Format Identifier (DSFID), HF only.

DLn

and where n:

E = Enable,

D = Disable

Allows locking the DSFID after writing (HF only).

En

where n:

E = Enable,

D = Disable

Allows erasures of the tag on error (HF only).

Lhh

where hh:

2-Chararacter Hex ID

Sets the Lock Code (Alien UHF only).

Mn

where n:

D = Disable

Disables the RFID module. (“N” is also a valid disabler.)

H = HF

Enables the RFID module for HF (Securakey).

U = UHF

Enables the RFID module for UHF Class 1 (Alien).

M = UHF

Enables the RFID module for UHF Multiprotocol.

(continued)