Extended System-Level Command Functions






62

Value

Interpretation

Input Mode Interpretation

8 PL-E

9 Auto

Character strings are automatically parsed and processed
according to the identified language.

A clean file is required, where extra leading characters
may cause the language to be unrecognizable;

otherwise, the appropriate Input Mode must be

selected.

10 CPCL

11

O’Neil EZ Print



(EN) End Character –
This command terminates a Kc string.


(EP) End of Print – This command defines the signal output used to signify the End

of Print (EOP) process:

Value

Units

End of Print Interpretation

1 Low

Pulse

Outputs a low pulse (approximately 30 milliseconds long)

following printing.

2 High

Pulse

Outputs a high pulse (approximately 30 milliseconds long)
following printing.

3

Active Low

Outputs a logic low (zero) following printing.

4

Active High

Outputs a logic high (one) following printing.



This manual is related to the following products: