System-Level Command Functions


15

4 System-Level

Command

Functions

Introduction

The most commonly used commands are the System-Level Commands. These are used to
load and store graphics information, in addition to printer control. System-Level Commands

are used to override default parameter values (fixed and selectable) and may be used
before or after Immediate Commands but cannot be issued among Label Formatting

Commands. System-Level Commands consist of:

1. Attention-Getter, 0x02 or 0x7E; see Control Code Command Functions.
2. Command Character
3. Parameters (if any).

STX A

Set Time and Date

This command sets the time and date. The initial setting of the date will be stored in the
printer’s internal inch counter. This date can be verified by printing a Configuration

Label.

Syntax:

AwmmddyyyyhhMMjjj

Where:

w

1 digit for day of week; 1 = Monday; 7 = Sunday

mm

2 digits for month

dd

2 digits for day

yyyy

4 digits for year

hh

2 digits for hour in 24 hour format

MM

2 digits for minutes

jjj

3 digits for Julian date / constant; see notes below.

Sample:

A1020319960855034

Printed response:

Mon. Feb 3, 1996, 8:55AM, 034

When set to 000, the Julian date is automatically calculated; otherwise, the Julian
date will print as entered, without daily increments. If factory defaults are restored

the actual Julian date will also be restored.

Printers without the Real Time Clock option lose the set time/date when power is

removed.

Response format is variable; see the Special Label Formatting Command T.