Extended System-Level Command Functions
95
STX KF
Select Factory Defaults
This command restores the configuration of the printer to the factory default settings.
These settings may be default values or the values previously specified by a
configuration file (see
Syntax:
Where:
n
- A = restore firmware settings including emulations
1 = restore firmware settings including network,
excluding emulations
2 = restores the factory settings (and, if saved, restoring
the Factory Setting File)
3 = restores settings excluding network and emulations
4 = reserved
5= reserved
6= reserved
7= restores network settings.
8 =restores settings excluding calibrations, emulations
and network
9 =restores calibration settings
Calibration will be required.
STX Kf
Set Present Distance
This command specifies an additional amount to advance the label after printing. This
command has the same effect as the
advance relative to the start of print (
Display-Equipped Models: SOP Emulation selection has no effect on this command.
Syntax:
Where:
nnnn
- A four-digit present distance in inches/100 or mm/10.
Sample:
The sample above represents a one-inch label advance unless in
metric mode (see