Extended System-Level Command Functions






51

Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Command

Equivalent

Rewinder Equipped

RM

A/Y, E, N/D

A or Y = Auto,

E = Enabled,

N or D = Disabled

N/A

RFID Configuration

RI

A, B, D, E, L, M,

N, P, R, S, T, U,

V, W

See Command

N/A

Ribbon Low Diameter

RL

100 – 200

1/100 in.

N/A

Ribbon Low Pause

RP

Y, N

Y = Enabled,

N = Disabled

N/A

Ribbon Low Signal

RS

3, 4

3 = Active Low,

4 = Active High

N/A

Row Adjust Fine Tune

RF

+ / – dots

Resolution specific; see Appendix K.

N/A

Row Offset

RO

0 – 9999

1/100 in.

Rnnnn

SOP Adjust

[1]

SA

0 – 255

(128 nominal)

N/A,

see Row Adjust Fine Tune

O

SOP Emulation

SE

A, L, P, D

A = Allegro,

L = Prodigy Plus,

P = Prodigy,

D = Disable

N/A