Appendix G – Bar Code Details

223

Syntax for GS1 DataBar (spaces added for readability):

a W1 k c d eee ffff gggg h i j m n…n | p…p

Where:

Field

Valid Inputs

Meaning

a

1,2,3, and 4

Rotation

W1

W1

Fixed value, extended bar code set

k

k

Selects GS1 bar code

c

1 to 9, A to Z, and a to z

Wide bar ratio, default = 2

d

1 to 9, A to Z, and a to z

Narrow bar ratio, default = 2

eee

000 No

effect

ffff

0000 to 9999

Label position, row

gggg

0000 to 9999

Label position, column

h

R, T, S, D, L

GS1 Type:

R = GS1 DataBar Omnidirectional,

T = GS1 DataBar Truncated,
S = GS1 DataBar Stacked,

D = GS1 DataBar Stacked Omni-Directional,

L = GS1 DataBar Limited

i

1-9 Pixel

Multiplier

j

0 to (i-1)

X pixels to undercut

m

0 to (i-1)

Y pixels to undercut

n…n

0 to 9

Numeric linear data, length 13

[1]

|

| (optional)

Vertical bar separates primary linear data from secondary
2-D data

p…p

2-D data (optional)

Additional 2-D data

[2]

[1]

The application identifier is not encoded in the symbol nor is the last check digit; the user

should enter in a 13-digit value. The decoding system will display the application identifier and
calculate the check digit.

[2]

The separator row height for two-dimensional composite is fixed at one times the pixel

multiplier.

Examples:

The following example prints an GS1 DataBar bar code:

L
D11
1W1k0000001500150R1002001234567890
121100000000100Barcode W1k
E

Barcode W1k