Extended System-Level Command Functions
102
STX KtE
Write Electronic Article Surveillance (EAS) Bit
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command writes the EAS bit for Philips ISO tags.
Syntax:
Where:
a
- The number of retry attempts, 0-9.
b
- Electronic Article Surveillance (EAS) option:
0 = Set EAS
1 = Reset EAS
2 = Test EAS
cc
- Two character Manufacturer’s Code, representing one
byte.
Sample:
The sample above writes the EAS bit for Philips (0x04), retrying
nine times if necessary.
STX KtH Read and Feedback Tag Information to Host
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command returns the tag info to host.
This command only works when the Data Flag for the tag is 0x0F (i.e., when the tag
contains DSFID, AFI, VICC and IC data).
Syntax:
Sample Feedback:
DATA FLAG: 0x0F
TAG ID: E004010000751412
DSFID: 0xE3
AFI: 0x01
NUM BLK: 0x1B
BLK SIZ: 0x03
IC REF: 0x01