5extended system-level command functions – Datamax-O'Neil DPL Programmer’s Manual User Manual
Page 41

Extended System-Level Command Functions
33
5
Extended System-Level
Command Functions
Introduction
Issued in the same context as System-Level Commands, the Extended System-Level
Commands expand certain System-Level Commands to provide an extra degree of printer
control.
STX K}E Empty Sensor Calibration
This command causes the printer to determine and save the calibration value for an
empty media sensor condition. This calibration function should be performed when no
material is installed in the media sensor. Depending upon the printer model, different
front panel LED flash sequences and printer responses (below) will indicate calibration
progress and outcome; see the corresponding printer operator manual for LED flash
sequences details.
Printer Response
Alternate
REMOVE STOCK[CR]
N/A
ENTER TO CONTINUE[CR]
N/A
PASSED CALIBRATION[CR]
FAILED CALIBRATION[CR]