beautypg.com

Datamax-O'Neil DPL Programmer’s Manual User Manual

Page 44

background image

Extended System-Level Command Functions

36

STX KaW Write Data to RFID Tag


(Direct Mode – Generic Read/Write Interface)

This command instructs the RFID device to write data to the tag. It is expected that the

tag transponder will be within the read / write distance of the RFID programming device;
otherwise, a warning will occur and a warning message (Read / Write Fail) will be
displayed.

Syntax:

KaWAaaabbbcdee…e

Where:

Aaaa

- Optional – for data in the ASCII format, followed by

the byte count (000-999).

bbb

- HF – Starting block number (000  maximum block

number, which is dependent upon the

transponder manufacturer).

UHF – Should be 000.

c

- Command 1. Reserved for Future (should be 0)

d

- Command 2. Reserved for Future (should be 0)

ee…e

- Data to be encoded on RFID tag (HF – the last used

block will be null-padded, if necessary).

UHF ASCII formats must be 8 or 12 characters; and,
UHF Hexadecimal formats must be 16 or 24
character pairs.

Sample:

KaW0000054455354[CR]

The sample above writes the data “TEST” at block zero.







STX Kb

Backfeed Time Delay

This command controls the time a printed label is allowed to remain “presented” before
being retracted to the start of print position.


Syntax:

Kbnnn

Where:

nnn

- Seconds/10 (0 to 255)

This manual is related to the following products: