Datamax-O'Neil DPL Programmer’s Manual User Manual
Page 44

Extended System-Level Command Functions
36
STX KaW Write Data to RFID Tag
(Direct Mode – Generic Read/Write Interface)
This command instructs the RFID device to write data to the tag. It is expected that the
tag transponder will be within the read / write distance of the RFID programming device;
otherwise, a warning will occur and a warning message (Read / Write Fail) will be
displayed.
Syntax:
Where:
Aaaa
- Optional – for data in the ASCII format, followed by
the byte count (000-999).
bbb
- HF – Starting block number (000 maximum block
number, which is dependent upon the
transponder manufacturer).
UHF – Should be 000.
c
- Command 1. Reserved for Future (should be 0)
d
- Command 2. Reserved for Future (should be 0)
ee…e
- Data to be encoded on RFID tag (HF – the last used
block will be null-padded, if necessary).
UHF ASCII formats must be 8 or 12 characters; and,
UHF Hexadecimal formats must be 16 or 24
character pairs.
Sample:
The sample above writes the data “TEST” at block zero.
STX Kb
Backfeed Time Delay
This command controls the time a printed label is allowed to remain “presented” before
being retracted to the start of print position.
Syntax:
Where:
nnn