Datamax-O'Neil DPL Programmer’s Manual User Manual
Page 39

System-Level Command Functions
31
STX Y
Output Sensor Values
This command causes a sensor value response. When
respond with the digitally converted values of the internal analog sensors (see below).
To repeat the display of values, send the printer a “SPACE” character (20 hexadecimal);
or, send
The printer must have Feedback Characters enabled for this command to function.
(Feedback Mode [Characters] can be enabled via command or menu setting; see the
command or the Operator’s Manual for additional information).
Syntax:
Printer response:
Thermistor ADC: 0048 Reflective ADC: 0000
Transmissive ADC: 0000 24 Volt ADC: 0217 Contrast ADC:
0093 TOF Adjust ADC: 0170 Ribbon ADC: 0125 Battery
Level: Good
Where:
Battery level:
Good indicates a sufficient battery charge;
Low
indicates an insufficient charge.
•
Equipped sensors vary with printer, model, and options;
•
Some readings require printer-controlled paper movement to produce a meaningful
value; and,
•
Media Sensor readings require the appropriate sensor selection, transmissive
(
) or reflective (
STX y
Select Font Symbol Set
This command selects the scalable font symbol set. The selected symbol set remains
active until another symbol set is selected. See the
E, I, and H for more information. Option dependent and not all symbol sets can be used
with all fonts.
Syntax:
Where:
S
- Byte-size designation; see Appendix H:
S
= Single byte symbol sets.
U = Double byte symbol sets.
xx
- Symbol set selection.
Sample:
The sample above selects the PC-850 multilingual set.