beautypg.com

Datamax-O'Neil DPL Programmer’s Manual User Manual

Page 219

background image

Appendix G – Bar Code Details

211

If HEX/ASCII mode is selected in manual Data Input Mode, only the data for Kanji or
Binary data types will be converted, therefore the other data types and all command

characters must be entered in ASCII format. If HEX/ASCII is selected in automatic
Data Input Mode, all of the data must be entered in HEX/ASCII format.


Data Append Mode String Format, Manual Formatting – Bar Code W1D

D aa tt pp I

Where:

Field

Valid Inputs

Meaning

D

D

Data Append Mode String Format indicator

aa

00, 99

QR Code Number in Append Series, 2 decimal digits

tt

The total number of QR Codes in series, 2 decimal digits

pp

Value of Parity, 2 digits, 8 LSBs of data parity

e

H, Q, M, L

As above

m

0 – 8, none

As above

i

A, a, M, m

As above

cdata

N, A, B, K

immediately followed

by data

As above

term

,

As above

Characteristics

Models:

Model 1 (original version), bar code versions 1 through 14

A. ECC Levels “H”, “M”, “Q”, and “L”

B. Mask Selection Automatic or 0 through 8
C. Data Input Modes Automatic and Manual

D. Data Append Mode

Model 2 (enhanced version), bar code versions 1 through 40

A. ECC Levels “H”, “M”, “Q”, and “L”
B. Mask Selection Automatic or 0 through 8

C. Data Input Modes Automatic and Manual
D. Data Append Mode

Representation of data:


Dark Cell = Binary 1
Light Cell = Binary 0

Symbol Size (not including quiet zone, 4 cells on each of the 4 sides):

This manual is related to the following products: