Appendix G – Bar Code Details

197

L:

Interleaved 2 of 5 (with a Modulo 10 Checksum and Bearer Bars)

Valid Characters: 0-9

Variable Length: For the bearer bars to be printed, 13 characters are required.

Valid bar widths: The expected ratio of wide to narrow bars can range from 2:1 to 3:1.

The following example prints an Interleaved 2 of 5 bar code with a modulo 10 checksum
with a wide to narrow bar ratio of 3:1 and bearer bars:

L
D11
1L00000001501000123456789012
121100000000100Barcode L
E

M:

2-Digit UPC Addendum


Valid Characters: 0-9


Length: 2 digits.

Valid bar widths: The fourth character of record is the width of the narrow bar in dots.

All other bars are a ratio of the narrow bar (2 times, 3 times, and 4 times the narrow
bar width). Human readable characters for this bar code symbology are printed above

the symbol.

The following example prints a 2 digit UPC bar code addendum:

L
D11
1M000000015010042
121100000000100Barcode M
E


N: 5-Digit

UPC

Addendum

Valid Characters: 0-9


Length: 5 digits.

Valid bar widths: The width multiplier is the width of the narrow bar in dots. All other
bars are a ratio of the narrow bar (2 times, 3 times, and 4 times the narrow bar width).

Human readable characters for this bar code symbology are printed above the symbol.