Symbol definitions, Command and response table, For ip-specific sis commands – Extron Electronics MPX 866 A User Guide User Manual
Page 77

Command and Response Table for IP-Specific SIS Commands
Symbol definitions
X2!
= Web page priority
0 = internal
1 = user
X2@
= Matrix name
(Up to 240 alphanumeric characters)
NOTE: The following characters are invalid or not recommended in the name: {space} + ~ , @ = ` [ ] { } < > ‘ “ ” ; : | \ and ?.
X2#
= Default name
Factory default name (model name + last 3 pairs of MAC address)
X2$
= Time and date (set)
In the format: MM/DD/YY•HH:MM:SS where:
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X2%
= Time and date (read)
In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where
Day = weekday: Mon through Sun
DD = day: 01 through 31
Mmm = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X2^
= GMT offset
-12.0 through +14.0 (hours and minutes removed from GMT)
X2&
= Daylight Savings Time
0 = Daylight Savings Time off/ignore
1 = Daylight Savings Time on (northern hemisphere)
2 = Daylight Savings Time on (Europe)
3 = Daylight Savings Time on (Brazil)
X2*
= IP address
###-###-###-###
X2(
= Hardware (MAC) address
##-##-##-##-##-##
X3)
= Number of open connections
0 - 255
X3!
= Password
12 alphanumeric characters
NOTE: The following characters are invalid or not recommended in passwords: {space} + ~ , @ = ` [ ] { } < > ‘ “ ” ; : | \ and ?.
X3@
= DHCP
0 = off, 1 = on
X3#
= Port #
01 = rear panel RS-232 Primary port
02 = rear panel RS-232 Secondary port/front panel Configuration port
NOTE: The rear panel RS-232 Secondary port (
X3#
= 02) is active only if the front panel Configuration port is not in use. If a front panel
configuration connection is made, the rear panel RS-232 Secondary port becomes inactive and the front panel Configuration port is
active.
X3$
= Baud rate
9600, 19200, 38400, 115200
X3%
= Parity
Odd, even, none, mark, space (only first letter required)
X3^
= Data bits
7, 8
X3&
= Stop bits
1, 2
X3*
= Verbose mode
0 = Clear/none (default for Telnet connection
1 = Verbose mode (default for RS-232 connection)
2 = Tagged responses for queries
3 = Verbose mode and tagged for queries
NOTE: If tagged responses is enabled, all read commands return the constant string and the value as the set command does (for example,
the read matrix name command,
E
CN
}
, returns IPN•
X2@]
).
X3(
= Security level
00 = Anonymous
11 = User
10 = Extended security levels 1 through 10
12 = Administrator
X4)
= Port timeout interval
1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)
MPX 866 A Media Presentation Matrix Switcher • Operation
72